JCM 344 . HNW MEDIUM

What is this page?
Equipment needed: Autoclave Filter

Final pH: 7.0

Select a strain (optional):

ml
Compound Amount Unit
MJ(-N) synthetic seawater 670.00 ml
NH4Cl 0.25 g
NaNO3 1.00 g
Na2WO4 x 2 H2O 0.10 mg
Distilled water 330.00 ml
1 Mix components thoroughly, adjust pH to 7.0 with NaOH and autoclave. After cooling, add the following solutions (filter-sterilized):
NaHCO3
(8%)
12.50 ml
Trace vitamins 10.00 ml
2 Aseptically distribute the medium into culture vessels (e.g., 20 ml in 120 ml serum bottles) under a H2-CO2 (4:1, v/v) gas mixture, and seal with butyl rubber stoppers. Pressurize inoculated bottles to 200 kPa H2-CO2 (4:1, v/v).
3 Comment: For JCM 34026, use 1.0 L of MJ(-N) synthetic seawater and omit distilled water.

MJ(-N) synthetic seawater #

1010