Back to all solutions

Main sol. 1003

Internal Solution-ID: S11

Equipment needed: Autoclave Anaerobic workbench
# Compound Amount Unit Conc. [g/L] Conc. [mM]
1 1000.00 - -
2 7.00 g 7 28.4
3 2.00 g 2 -
4 0.40 g 0.4 2.721
5 0.48 g 0.48 6.439
6 0.78 g 0.78 8.192
7 1.95 g 1.95 9.988
8 Solution A (100x solution) 2.00 ml - -
9 Solution B (500x solution) 1.50 ml - -
10 Trace mineral solution (100x) 10.00 ml - -
Instructions:
  1. Place 1000 ml of anaerobic water (CO2 water) in a flask. Add the following compounds: #2-7
  2. Add solutions A, B, and D (see recipes below):
  3. pH the media to 6.0 and gas the flask containing the media with CO2 for 20 min at least. Gas first culture tube in rack and place 5 ml of media in previous tube. Place stopper on loaded culture tube, crimp tube cap onto stopper. Autoclave the medium for 20 min., 121°C. Add 1 ml of O2 to each tube before inoculation. After the inoculation the tubes are pressurized with H2 (138 KP).
1003 HYDROGEN-OXYDIZING MEDIUM