Back to all solutions

Main sol. 875

Internal Solution-ID: S1808

Equipment needed: Gassing station Autoclave Hungate tubes Filter
Compound Amount Unit Conc. [g/L] Conc. [mM]
Solution A 950 ml - -
Solution B 1 ml - -
Solution C 30 ml - -
Solution D 1 ml - -
Solution E 10 ml - -
Solution F 10 ml - -
1 Solution A is sparged with 80% N2 and 20% CO2 gas mixture to reach a pH below 6 (at least 30 - 45 min), then distributed under the same gas atmosphere into anoxic Hungate-type tubes or serum vials and autoclaved. Solutions B, E and F are autoclaved separately under 100% N2 gas atmosphere. Solution C is autoclaved under 80% N2 and 20% CO2 gas atmosphere. Solution D is prepared under 100% N2 gas atmosphere and sterilized by filtration. To complete the medium appropriate amounts of solutions B to F are added to the sterile solution A in the sequence as indicated. Final pH of the medium should be 7.0 - 7.3.
875 DESULFACINUM HYDROTHERMALE MEDIUM