Back to all solutions

Main sol. J1093

Internal Solution-ID: S5164

Equipment needed: Autoclave Filter
Compound Amount Unit Conc. [g/L] Conc. [mM]
MJ(-N) synthetic seawater 1000.00 ml - -
NH4Cl 0.25 g 0.123 2.307
KNO3 0.25 g 0.123 1.221
Distilled water 1000.00 ml - -
1 Mix components thoroughly and autoclave. After cooling, add the following solutions (filter-sterilized):
NaHCO3
(8%)
10.00 ml - -
Na2S2O3 x 5 H2O
(10%)
15.00 ml - -
Trace vitamins 1.00 ml - -
2 Aseptically distribute the medium into culture vessels (e.g., 20 ml in 120 ml serum bottles) and seal with butyl rubber stoppers. Replace the gas phase with a N2-CO2 (80:20, v/v) gas mixture, and pressurize to 200 kPa. Adjust pH to 6.0, if necessary.
J1093 MJ BASAL MEDIUM WITH THIOSULFATE/2