Back to all solutions

Main sol. 462a

Internal Solution-ID: S935

Equipment needed: Autoclave
Compound Amount Unit Conc. [g/L] Conc. [mM]
Medium 462 1000 ml - -
Fluoranthene
(dissolved in acetone)
trace 2 9.889
1 Pour plates of medium 462. Dissolve 2 mg/ml fluoranthene in acetone and spread 1 ml of this solution on the surface of every pre-dried plate. Allow the acetone to evaporate under sterile conditions. Inoculate as usual.
462a PLATES WITH FLUORANTHENE