DSMZ 503 . ANAEROBIC FRESHWATER (FWM) MEDIUM

What is this page?
Equipment needed: Autoclave Filter Gassing station Hungate tubes

Final gas composition: 80 % N2 20 % CO2 read more

Final pH: 7.2 - 7.4

Select a strain (optional):

Main sol. 503 #

ml
Compound Amount Unit
Solution A 942 ml
Solution B 30 ml
Solution C 20 ml
Solution D 1 ml
Solution E 10 ml
1 Sparge solution A with 80% N2 and 20% CO2 gas mixture for 30 - 45 min to make it anoxic, distribute under same gas atmosphere into anoxic Hungate-type tubes or serum vials and autoclave. Solution B is autoclaved separately under 80% N2 and 20% CO2 gas atmosphere. Solution C and D are prepared under 100% N2 gas and sterilized by filtration. Solution E is autoclaved under 100% N2 gas. To complete the medium appropriate amounts of solutions B to E are added to the sterile solution A in the sequence as indicated. Adjust pH of complete medium to 7.2 - 7.4, if necessary.

Solution A #

942
Compound Amount Unit
KH2PO4 0.20 g
NH4Cl 0.25 g
NaCl 1.00 g
MgCl2 x 6 H2O 0.40 g
KCl 0.50 g
CaCl2 x 2 H2O 0.15 g
Trace element solution SL-10 1.00 ml
Selenite-tungstate solution 1.00 ml
Sodium resazurin
(0.1% w/v)
0.50 ml
Distilled water 940.00 ml

Solution B #

30
Compound Amount Unit
Na2CO3 1.5 g
Distilled water 30.0 ml

Solution C #

20
Compound Amount Unit
D-Glucose 5 g
Distilled water 20 ml

Solution D #

1
Compound Amount Unit
Seven vitamins solution 1 ml

Solution E #

10
Compound Amount Unit
Na2S x 9 H2O 0.3 g
Distilled water 10.0 ml

Trace element solution SL-10 #

1000
Compound Amount Unit
HCl
(25%)
10.0 ml
FeCl2 x 4 H2O 1.5 g
ZnCl2 70.0 mg
MnCl2 x 4 H2O 100.0 mg
H3BO3 6.0 mg
CoCl2 x 6 H2O 190.0 mg
CuCl2 x 2 H2O 2.0 mg
NiCl2 x 6 H2O 24.0 mg
Na2MoO4 x 2 H2O 36.0 mg
Distilled water 990.0 ml
1 First dissolve FeCl2 in the HCl, then dilute in water, add and dissolve the other salts. Finally make up to 1000.00 ml.

Selenite-tungstate solution #

1000
Compound Amount Unit
NaOH 0.5 g
Na2SeO3 x 5 H2O 3.0 mg
Na2WO4 x 2 H2O 4.0 mg