Back to all solutions

Main sol. 503b

Internal Solution-ID: S1060

Equipment needed: Filter Gassing station Hungate tubes Autoclave
Compound Amount Unit Conc. [g/L] Conc. [mM]
Solution A 950 ml - -
Solution B 30 ml - -
Solution C 10 ml - -
Solution D 1 ml - -
Solution E 10 ml - -
1 Sparge solution A with 80% N2 and 20% CO2 gas mixture for 30 – 45 min to make it anoxic, distribute under same gas atmosphere into anoxic Hungate-type tubes or serum vials and autoclave. Solution B is autoclaved separately under 80% N2 and 20% CO2 gas atmosphere. Solutions D and E are prepared under 100% N2 gas and sterilized by filtration. To complete the medium appropriate amounts of solutions B to E are added to the sterile solution A in the sequence as indicated. Adjust pH of complete medium to 7.0 - 7.2, if necessary.
503b FWM MEDIUM (PERCHLORATE)