Back to all solutions

Main sol. 163

Internal Solution-ID: S279

Equipment needed: Autoclave Gassing station Hungate tubes
Compound Amount Unit Conc. [g/L] Conc. [mM]
Solution A 980 ml - -
Solution B 10 ml - -
Solution C 10 ml - -
1 Bring solution A to the boil, then cool to room temperature while sparging with 100% N2 gas. Add solutions B and C, adjust pH to 7.8 with NaOH, and distribute under N2 gas atmosphere into anoxic Hungate-type tubes. During distribution continuously swirl the medium to keep the grey precipitate suspended. Autoclave 15 min at 121°C. Adjust pH of the complete medium to 6.8 - 7.0, if necessary.
163 HALODESULFOVIBRIO (POSTGATE) MEDIUM