Equipment needed: Autoclave
Compound Amount Unit Conc. [g/L] Conc. [mM]
NaCl 256.00 mg 0.256 4.381
KH2PO4 1.70 mg 0.002 0.012
CaCl2 x 2 H2O 0.80 mg 8.0e-4 0.005
H3BO3 10.30 mg 0.01 0.167
Na2SO4 23.00 mg 0.023 0.162
NaNO3 0.30 mg 3.0e-4 0.004
KCl 15.00 mg 0.015 0.201
FeCl3 x 6 H2O 0.10 mg 1.0e-4 3.7e-4
MnSO4 x 4 H2O 0.06 mg 6.0e-5 2.7e-4
Modified Wolin's mineral solution II 10.00 ml - -
Distilled water 1000.00 ml - -
1 Sparge medium with 100% N2 gas mixture for 30 min to make anoxic.
2 Adjust pH to 7.0 with H2SO4.
3 Fill 10 ml medium into 100 ml Serum bottles under a stream of H2/CO2 gas and seal with a rubber stopper.
4 Autoclave at 121 °C for 20 min.
5 After autoclaving add the following (e.g., from sterile stock solutions)
Na2S2O3 x 5 H2O
(10% in H2O)
1.00 g/l 1 4.029
NaHCO3
(5 % in H2O)
1.00 g/l 1 11.904
6 Adjust the gas atmosphere strain specifically.
887 OS MEDIUM