Back to all solutions

Main sol. 1398

Internal Solution-ID: S2834

Equipment needed: Autoclave Filter Hungate tubes
Compound Amount Unit Conc. [g/L] Conc. [mM]
S I 75.0 ml - -
S II 75.0 ml - -
Trypticase 1.0 g 1 -
Yeast extract 0.5 mg 5.0e-4 -
Glucose 1.0 g 1 5.551
L-Cysteine HCl 0.3 mg 3.0e-4 0.002
Resazurin
(0.1%)
0.5 ml 5.0e-4 0.002
100x Vitamin solution 10.0 ml - -
Distilled water 1000.0 ml - -
1 SII
2 pH 7.0
3 Prepare the medium without the vitamin solution under an atmosphere of N2 and dispense into Hungate tubes. Seal under an atmosphere of nitrogen with rubber stoppers and autoclave. Aseptically add the vitamin solution from a filter sterilised stock solution to the sterile medium.
1398 1/10 PYGV MEDIUM modified