JCM 1003 . ACIDIC HB-1 MEDIUM

Inofficial medium: This medium was provided by external sources and is possibly not curated by experts.

Culture medium recipe

Vol.
×
Equipment needed: Anaerobic workbench
Compound Amount Unit Conc. [g/L] Conc. [mM]
Medium J744 1000 ml - -
1 Use Medium No. 744. Before autoclaving, adjust pH of the medium to 5.5. After autoclaving, add per liter the following solutions aseptically and anaerobically from anaerobic stocks:
KNO3
(10%)
20 ml - -
MES
(pH 5.5, 20%)
25 ml - -
Na2S x 9 H2O
(neutralized, 3%)
4 ml - -
2 Otherwise, prepare the medium as described in the recipe of Medium No. 744.
Solution occurs in 1 other media (first defined in Medium J744).
Equipment needed: Autoclave Anaerobic workbench
Compound Amount Unit Conc. [g/L] Conc. [mM]
NaCl 20.000 g 19.066 326.245
MgSO4 x 7 H2O 3.500 g 3.337 13.537
MgCl2 x 6 H2O 2.750 g 2.622 12.895
KCl 0.325 g 0.31 4.156
NaBr 0.050 g 0.048 0.463
H3BO3 0.015 g 0.014 0.231
SrCl2 x 6 H2O 7.500 mg 0.007 0.027
(NH4)2SO4 10.000 mg 0.01 0.072
KI 0.500 mg 4.8e-4 0.002
Na2WO2 x 2 H2O 0.100 mg 9.5e-5 -
CaCl2 x 2 H2O 0.750 g 0.715 4.863
KH2PO4 0.500 g 0.477 3.503
NiCl2 x 6 H2O 2.000 mg 0.002 0.015
Trace minerals (see Medium No. 151 10.000 ml - -
Resazurin 1.000 mg 9.5e-4 0.004
Distilled water 1000.000 ml - -
1 Mix ingredients, bring to a boil and cool under a H2-CO2 (4:1, v/v) gas mixture. Slowly add 10 ml 5% Na2S x 9H2O solution to the medium, wait for the medium to become colorless, then adjust pH to 7.0 with NaOH. Distribute medium into culture vessels under the same gas mixture, seal with butyl rubber stoppers and autoclave. Before inoculation, aseptically and anaerobically add per liter the following solutions from anaerobic stocks (autoclaved and stored under a N2 atmosphere):
KNO3
(10%)
10.000 ml - -
PIPES
(pH 7.0, 0.05 M)
25.000 ml - -
Na2S x 9 H2O
(neutralized, 3%)
4.000 ml - -
2 Pressurize the inoculated culture vessels to 200 kPa H2-CO2 (4:1, v/v).

Metadata

Last modified: 22.02.22
Source: JCM
Taxonomic range:  Bacteria
Medium type: Defined medium
Final pH: 5.5
Equipment needed: Anaerobic workbench, Autoclave
Edit in Medium builder

Associated strains

All strains for this medium: 1

Molecular composition

Compound Conc. [g/L] Conc. [mM]
KNO3 - -
MES - -
Na2S x 9 H2O - -

Cultivation metadata from 1 strains BacDive

phyla 1 1 strain
oxygen anaerobe 1 strain
temperature thermophilic 1 strain