Back to all solutions

Main sol. 1100

Internal Solution-ID: S2216

Equipment needed: Autoclave Hungate tubes Gassing station
Compound Amount Unit Conc. [g/L] Conc. [mM]
Na2SO4 3.00 g 2.947 20.747
KH2PO4 0.20 g 0.196 1.444
NH4Cl 0.30 g 0.295 5.509
NaCl 7.00 g 6.876 117.663
Trace element solution SL-11 1.00 ml - -
Selenite-tungstate solution 1.00 ml - -
MgCl2 x 6 H2O 3.10 g 3.045 14.979
KCl 0.50 g 0.491 6.588
CaCl2 x 2 H2O 0.15 ml - -
Yeast extract 0.50 g 0.491 -
Sodium resazurin
(0.1% w/v)
0.50 ml 4.9e-4 0.002
NaHCO3 1.50 g 1.473 17.54
Na-L-lactate 2.00 g 1.965 -
Neutralized sulfide solution 3% (w/v) 15.00 ml - -
Distilled water 1000.00 ml - -
1 Dissolve ingredients (except bicarbonate, lactate and sulfide) and sparge medium with 100% N2 gas for 30 - 45 min to make it anoxic. Dispense medium under same gas atmosphere into anoxic Hungate-type tubes or serum vials and autoclave. Add lactate and sulfide form sterile anoxic stock solutions prepared under 100% N2 gas and bicarbonate from a sterile anoxic stock solution prepared under 80% N2 and 20% CO2 gas mixture. Adjust pH of the complete medium to 7.2, if necessary.
1100 DESULFACINUM MEDIUM